Sump Test System

The Sump Test System (STS) is designed specifically to test containment for leaks. Up to four containments can be leak-tested simultaneously with accurate compliance test results available in just 15 minutes.

Highlights
Specs
Order Info
Downloads
  • Highlights

    • Designed to deliver cost-effective environmental compliance test data.
    • Easily transported in two supplied carrying cases.
    • Easily set-up and programmed with site-specific data and sump identification before a test. Site and test data can also be saved to a laptop.
    • Laptop interface optional using System Sentinel™ Tech Software.
    • Accommodates up to four probes for testing of up to four spill containers, dispenser sumps, or tank sumps simultaneously.
    • Uses magnetostrictive probe technology for unparalleled accuracy and reliable results.
    • Highly accurate leak test detects level changes greater than 0.002 inches during the fifteen minute test.
    • Provides accurate test fluid levels for each sump monitored.
    • Automatically prints out passed or failed test reports in just fifteen minutes after starting a leak test. Printer included.
    • Shows the date and time of the test, test fluid levels, and the leak test results on sump leak test reports.
    • Additional sump leak test reports can also be printed at the console before other tests are completed.
  • Specs

    • Operating temperature:
    • Console: 32° to 122 °F (0° to 50 °C)
    • Leak test probes: -40° to 140 °F (-40° to 60 °C)
    • Storage temperature:
    • Console: -4° to 140 °F (-20° to 60° C)
    • Leak test probes: -40° to 158 °F (-40° to 70 °C)
    • Intrinsic safety rating:
    • Leak test probes: Class 1, Div. 1, Group D
    • Carry case weight and dimensions:
    • Console: 33 lbs. (15 kg), 24" × 19" × 8½" (62 cm × 49 cm × 22 cm)
    • Leak test probes: 30 lbs. (13.5 kg), 38" × 18" × 6" (97 cm × 45 cm × 16 cm)
    • Number of sumps monitored:
    • Console: 4
    • Leak test probes: 1
    • Applicable liquids:
    • Leak test probes - testing solution.
    • Level units:
    • Console - inches.
    • Display type and size:
    • Console - alphanumeric LCD,
    • 2 lines of 40 characters.
    • Printer type:
    • Console - 24 column thermal printer.
    • Power requirements:
    • Console - 115 VAC, 50 Watts, 6' power cord with 3 prong plug supplied.
    • Leak test probes - 50' cable supplied.
  • Order Info

    ModelDescription
    TS-STS-2KSump test system with two probes
    TS-STS-3KSump test system with three probes
    TS-STS-4KSump test system with four probes
  • Downloads