TS-550/5000 Fuel Management System with Upgraded Thermal PrinterThe same great tank gauge which provides compliance and fuel management capabilities in a single, modular enclosure now has even more value with the addition of the upgraded thermal printer option. Check out the added benefits in the “Thermal Printer” tab or download the T5 Series Brochure below.
Click here to view the T5 Series Thermal Printer Sales Brochure
|
The flexible architecture of the INCON fuel management system allows multiple applications to run concurrently, satisfying current and future business and regulatory requirements.
The INCON fuel management system is built on established open system software platform.
| Intrinsic Safety Rating | US: Class I, Div. I, Group D Europe: Group IIA, Zone 0 |
| Operating temperature | 32° to 104° F (0° to 40° C) |
| Storage temperature | -4° to 140° F (-20° to 60° C) |
| Power requirements | 110-220 VAC, +15%, -10%, 150 Watt maximum, 1.5 Amp |
| PART NUMBER | DESCRIPTION |
|---|---|
| TSSP-CM | Control Module |
| TSSP-PS | Power Supply Module |
| TSSP-IFB5 | TS-5 Interface Board |
| TSSP-IFB5X | TS-550 / 5000 Interface Board |
| TSSP-T5MB | TS-5 Motherboard |
| TSSP-T550MB | TS-550 Motherboard |
| TSSP-T5000MB | TS-5000 Motherboard |
| TSSP-LCD | LCD Display |
| TSSP-IPPTR | Impact Printer Assembly |
| TSSP-TRMBLK | Package of 10 Terminal Blocks |
| MODEL | DESCRIPTION |
|---|---|
| TS-5000 110 VAC & 220 VAC Models | |
| T5000 | TS-5000 base console, without display and printer |
| T5000D | TS-5000 base console, with display and without printer |
| T5000DP | TS-5000 base console, with display and printer |
| TS-550 110 VAC & 220 VAC Models | |
| T550 | TS-550 base console, without display and printer |
| T550D | TS-550 base console, with display and without printer |
| T550DP | TS-5000 base console, with display and printer |
| Expansion Console | |
| TS-EXPC | Secondary Console to add eleven additional plug-in modules to primary TS-5000/550 console. No display or printer. |
The TS-550 and TS-5000 consoles come standard with the ability to monitor inventory levels and perform Static Tank Leak Detection. The following software and hardware options can be added to customize your consoles. The internal hardware options will be factory installed when ordered with the console.
| PART | DESCRIPTION |
|---|---|
| Internal Software Option | |
| TS-TT | (T) Statistical Continuous Automatic Leak Detection Tank Testing Software (SCALD) |
| TS-TRAC | (R) Tank Inventory Reconciliation and Auto Calibration |
| TS-ELLD | (L) Electronic Line Leak Detection |
| TS-VRM | (V) Vapor Recovery Monitoring |
| TS-SCM | (S) Secondary Containment Monitoring |
| Internal Hardware Option | |
| TS-DIMIB | (I) Internal Dispenser Interface Module (Dispenser Interface Cable must be ordered separately) |
| TS-LON | (E) EcheLON Communication Module (IFSF protocol capability) |
| TS-MDMIB | (M) Internal Modem (Includes fax and data software capability) |
Note: Only one TS-DIMIB or TS-LON module can be installed per console.
The TS-550 and TS-5000 consoles come standard with a power supply module and a controller module. Additional interface modules can be installed. Interface modules ordered with a TS-550/5000 console will be installed in the console at the factory. The following guidelines must be followed: TS-5000: Eleven total modules can be installed with a maximum of nine intrinsically safe modules, a maximum of three of any one kind of module. TS-550: Six total modules can be installed with a maximum of four intrinsically safe modules, a maximum of three of any one kind of module.
Intrinsically Safe Modules
| PART NUMBER | DESCRIPTION |
|---|---|
| TS-PRB | 12 Input Probe Module (LL2 Series Mag Probes and VFM Series Flow Meters) |
| TS-2WSNS | 12 Input 2-wire Sensor Module (TSP-ULS and TSP-HLS Sensors) |
| TS-3WSNS | 8 Input 3-wire Sensor Module (TSP-EIS, DIS, DDS, DTS, HIS and DVS Sensors) |
| TS-420IB | 8 Input 4-20 ma Module (LSU500 Transducers and VPS & VCM Series Pressure Sensors) |
Non-Intrinsically Safe Modules
| PART NUMBER | DESCRIPTION |
|---|---|
| TS-ACI | 12 Input AC Input Module (Dispenser Hook Inputs) |
| *TS-RLY | 8 Input Relay Output Module (VCM Series Solenoid) |
| TS-10ARLY | 6 output 10 Amp relay outputm module, dispenser power |
| TS-IO | INput output module, 4 output 4-20mA, 8 input 3-240 VAC/DC |
| TS-420EXP | 8 input 4-20mA module, LSU500E transducers and external devices |
| *NOTE: TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications | |
Pressurized line leak detection provides automatic 3.0 gph hourly, 0.2 gph monthly and 0.1 gph annual precision line leak detection for TS-550 and TS-5000 consoles. A TS-420IB, TS-ACI and TS-RLY module and TS-ELLD software option must be ordered and installed in tank gauge console.
| PART NUMBER | DESCRIPTION |
|---|---|
| TS-LS500/2 | 2-line transducer kit |
| TS-LS500/3 | 3-line transducer kit |
| TS-LS500/4 | 4-line transducer kit |
Note: Using turbine pump interface (TPI) communications eliminates the need for a TS-RLY module (FFS intelligent controllers required).
| PART NUMBER | DESCRIPTION |
|---|---|
| TSP-WDCBL | Wayne DIM Cable |
| TSP-TDCBL | Tokheim DIM Cable |
| TSP-GDCBL | Gilbarco DIM Cable |
| TSP-GSDCBL | Gilbarco G-Site DIM Cable |
The secondary containment monitoring system is designed to detect leaks in double-walled tanks, sumps and piping. A TS-420IB, TS-RLY module, TS-ACI and TS-SCM software option must be ordered and installed in the tank gauge console.
Sensor Modules
| PART NUMBER | DESCRIPTION |
|---|---|
| TS-SCCM/1 | Single Secondary Containment Control Module |
| TS-SCCM/2 | Double Secondary Containment Control Module |
| TS-SCMCAL | Leak Generator Kit (one per station) |
Install Kit
| PART NUMBER | DESCRIPTION |
|---|---|
| TSP-SCLSI | Product/Vapor Line/Sump Containment Install Kit |
| TSP-SCTKI | Tank Containment Install Kit (in tank hose sold separately) |
Accessories
| PART NUMBER | DESCRIPTION |
|---|---|
| TSP-SCTB25 | 25 foot hose |
| TSP-SCTB50 | 50 foot hose |
| TSP-SCTB100 | 100 foot hose |
| TSP-SCCLP | Five hose clamps |
| TSP-SCVLV | Five Schraeder valves |
| TSP-SCBRB | Five 1/4" NPT barbed fittings |
| TSP-SCBRBT | 1/4" NPT barbed T fitting |
Franklin Fueling Systems continuously strives to improve and upgrade its product offering, providing better quality, more value and the latest technology to its customers. The newest product enhancement is the thermal printer, now standard on T5 Series tank gauges. This thermal printer features: