Model 1250B:
|
For many years this versatile instrument has been a Utility and Industrial standard for measurement of:
Model 1292 - Synchro Transmitter
Model 1292K - Transmitter w/bracket
Model 1292KS - Transmitter w/bracket and surge protection circuit
Model 1293 - Flexible coupling shaft
Model 1945 - 15 VDC Loop Power Supply (For 4-20 mA Analog Output)
Model 1280 - Surge Protection Module
Model RD-4 - Remote Display
| GENERAL | |
|---|---|
| Input Signal | Synchro (5 wire) 90V maximum |
| Resolution | +/-0.001% of full scale or 6 arc minutes |
| Accuracy | +/-0.02% of full scale maximum (.01% typical) |
| Temperature Drift | +/- 0.01% per °C |
| Operating Temperature | 0° to 55° C (standard) |
| Humidity | 10% - 90% non condensing |
| Weight | 24 ounces |
| Voltage | 117/234 +/- 10% |
| Frequency | 47 - 63 Hz |
| Load | 8 Watts, maximum |
| DISPLAY | |
| Type | 5-digit LED |
| Digit Height | 0.56 inch (14.2 mm) |
| Viewing distance | 23 feet |
| Decimal point | Field programmable (scaled modes only) |
| OPTIONAL ANALOG OUTPUT | |
| Outputs | +/- 1 mA, 0-1mA, 0-2mA, 4-20mA (requires external loop power) |
| Compliance | 10 Volts (0-1mA, +/-1mA, 0-2mA) 500 Ohms (4-20mA) |
| Non-Linearity | +/- 0.1% of full scale |
| Resolution | 12 bits (+/- 0.025% of full scale) |
| OPTIONAL HI/LO RELAYS | |
| Contact Rating | 3A @ 125/250 VAC (resistive), 30 VDC |

Panel cut out min.: 1.653 (42mm) x 3.543
(90mm)
(+2 / -0 mm)
Panel thickness: 0.1 (2.7mm) to 0.19 (5.0mm)
| 1250B-U-W-X-Y-ZZZ = options, see below | |
| OPTIONS | |
|---|---|
| U = Output Options | 0 (0-1 mA) 2 (0-2 mA) 1 (±1 mA) 4 (4-20 mA) |
| W = Control | R - Hi/Low Relay Limits |
| X = Input Option | I - Input Isolation |
| Y = Comm. Options | S - RS-232 M RS-485 MODBUS PB Parallel Data (BCD) |
| ZZZ = Line Voltage | 120 (120 VAC) or 240 (240 VAC) |