Specifications

Power Requirements

  • Fixed Length, Fixed Speed models require single phase, 208-230 VAC, 60 Hertz incoming power
  • Fixed Length, Fixed Speed models are available in 1/3 hp, 3/4 hp, 1-1/2 hp, & 2 hp versions
  • Fixed Speed models incorporate a starting & running capacitor, with internal bleed resistor
  • A 370 Volt, 15 microfarad rated capacitor is used with 1/3 hp, 3/4 hp, & 1-1/2 hp Fixed Length, Fixed Speed versions
  • A 370 Volt, 40 microfarad rated capacitor is used with 2 hp Fixed Length, Fixed Speed versions
  • STP-SCI Single Phase Smart Controllers and STP-CBS Single Phase Control Boxes are available for Fixed Speed pump control

Pump Motor

  • Fixed Speed, 3450 rpm, multi-stage centrifugal type pump motor with integral, automatic, thermal overload protection
  • 1-1/2 hp & 2 hp Fixed Speed models are available in Standard Pressure (2 stage) versions and High Pressure (H option, 3 stage) versions
  • 1/3 & 3/4 hp Fixed Speed models are both available as 2 stage versions

Liquid Compatibility

    Max liquid viscosity: 70 SSU @ 60°F (15°C)
  • Fixed Length STP (Non-AG) models are UL and cUL listed for fuel mixtures containing up to 10% Ethanol or Methanol, and 20% MTBE, 20% ETBE, or 17% TAME with gasoline.
  • AG (Alcohol-Gasoline) models are UL and cUL listed for fuel mixtures containing up to 85% Ethanol or Methanol, and 20% MTBE, 20% ETBE, or 17% TAME with gasoline.
  • Fixed Length models can also be used with Diesel Fuels, Fuel Oils, Kerosene, Avgas, and Jet Fuels in a non-gelled pourable state.
  • All wetted elastomers are made of a high grade, fluorocarbon viton compound.

Standard Features

  • Check Valve: 2-3/4 diameter fluorocarbon viton seal constructed on cast aluminum body and steel backing washer
  • Pressure Relief Valve: available in four pressure relief settings, integral to Check Valve. Standard Model relieves at 40 psi and resets above 35 psi.
  • Syphon: venturi type syphon primer supplied with every submersible. Syphon Check Valve and Secondary Syphon sold separately.
  • Air Eliminator: every submersible includes tank return path, with one-way check valve, to provide active air elimination
  • Electrical Disconnect: electrical yoke for positive contractor disconnect during service

Approvals

  • Fixed Length models are UL and cUL listed
  • Consult factory for other applicable approvals

Quality Certification

  • Franklin Fueling Systems is an ISO 9001
  • Certified Manufacturer

Designation System


    Click here to view the diagram.

    A typical turbine model designation has up to five components to define the pump being supplied as follows:

    IST YYYYY A - B - C

    IST = Basic Model Designation
    Note: All IST models include the options of alcohol-gasoline compatibility, variable speed, and variable length as part of the base model.

    YYYYY = Factory Installed Options
    IST model designations may include one or more of the following characters in alphabetical order:

    F = Floating suction adapter (1 1/2” NPT female adapter)
    K = Intake filter screen (IFS, factory installed to PMA) M = MagShell™ (flow enhancing expanded PMA shell)
    *R = Model R check valve (24 psi relief/22 psi reset for PLLD)
    *W = Model W check valve (16 psi relief/13 psi reset for PPM4000)

    *Note: if not otherwise specified, all IST models are supplied with standard model check valve (40 psi relief/35 psi reset for MLD and LS300)

    A = Pump Motor Horsepower Rating**
    VS4 = 4 hp variable speed

    **Note: If not otherwise specified, 2 hp variable speed is implied.

    B = Model Length
    1 = 2 hp variable length range 59” – 87”
    2 = 2 hp variable length range 90” – 151”
    3 = 2 hp variable length range 122” – 213”
    VL1 = 4 hp variable length range 64” – 92”
    VL2 = 4 hp variable length range 95” – 156”
    VL3 = 4 hp variable length range 127” – 218”

    Note: IST-2 and ISTVS4-VL2 models fit 94% of all known installations.

    C = Riser Pipe Length
    Note: Riser pipe length is expressed as two numeric characters that indicate the total length of the riser in inches. Riser pipes are available from 7” to 69” in one inch increments
    (add’l charge for risers 31” or longer)

 

Ordering Information

Fixed Length Submersible Turbines Pumps

Non-AG Model Number Description Model* Length Range
STP 33 1/3 hp Fixed Speed 37”-132”
STP 75 3/4 hp Fixed Speed 37”-132”
STP 150 1-1/2 hp Fixed Speed 37”-132”
STP H 150 High Pressure, 1-1/2 hp Fixed Speed 37”-132”
STP M 200 2 hp Fixed Speed with MagShell 37”-132”
STP H M 200 High Pressure, MagShell, 2 hp Fixed Speed 37”-132”

    1. Remove “M” from Model Number for non-MagShell Pump Motor Assembly.
    2. Above models are UL and cUL listed for compatibility with fuel mixtures containing:
    STP (Non-AG) = up to 15% Ethanol or Methanol with Gasoline, and 20% MTBE, 20% ETBE, or 17% TAME with Gasoline.
    STPAG (Alcohol-Gasoline) = up to 100% Ethanol or Methanol with Gasoline, and 20% MTBE, 20% ETBE,
    or 17% TAME with Gasoline.
    3. All models are supplied with Standard Check Valve unless factory option “R” or “W” is specified.
    4. All above models require Single Phase, 208-230 VAC, 60 Hertz incoming power
    * Model Length (B) defined as the dimension from Turbine Manifold bottom to Pump Motor inlet.
    Model Length (B) can be a minimum of 37” to a maximum of 211”
    Adder charge to List if Model Length (B) is 133” to 180” (charge is for boards to protect STP shipment)
    Adder charge to List Price (do not apply discount) if Model Length (B) is 180” to 211” (charge is for crating STP)
    ** 4” Riser Pipe, if supplied locally, must be 4 1/2” OD by 3/16” wall thickness tubing.
    *** For Riser Pipe lengths 31” to 69”, adder charge applies.

Factory Installed Options (specified in Model Number at time of STP order)

Model Designation Description
AG Alcohol-Gasoline compatibility (for fuel mixtures up to 100% Ethanol or Methanol)
F Floating Suction Adapter (1-1/2” NPT Female) must be factory installed
K IFS (Intake Filter Screen) factory assembled to Pump Motor Assembly
R Model R Check Valve factory installed (for Veeder Root PLLD Line Leak)
W Model W Check Valve factory installed (for Red Jacket PPM4000 Line Leak)

Field Installed Options (1/3 & 3/4 hp Fixed Speed specific accessories)

Part Number Description
5800100215 STP-SCI (Single Phase Smart Controller, when purchased without a 4 inch STP)
5800100215 STP-SCI (Single Phase Smart Controller, when purchased with a 4 inch STP)*
5800300100 STP-DHI (Dispenser Hook Isolation for 110V dispenser handle switches, up to 8 each)
402312921 STP-DHI-SCI (combo DHI with factory wired STP-SCI, when purchased without a 4 inch STP)*
402312921 STP-DHI-SCI (combo DHI with factory wired STP-SCI, when purchased with a 4 inch STP)
402313921 STP-DHI-CBS (combo Dispenser Hook Isolation with factory wired STP-CBS)
400818921 STP-CBS (Single Phase Control Box with lockout switch, 110V coil)
400137908 Syphon Check Valve (Alcohol-Gasoline compatible) when ordered with STP
402507930 Secondary Syphon Kit (when two syphon primes are required for one STP)
402459931 Model 65 PSI Check Valve (for Slave of manifolded STP’s with Veeder Root PLLD)
    Note: *When purchasing STP-SCI or STP-DHI-SCI in equal quantities of Fixed Speed 4 inch STPs, the STP-SCI or STPDHI-
    SCI will be invoiced at special discount pricing.