The EBW 325 product line isolation valve (PLIV) is designed to be installed at the top of the underground storage tank fuel line fitting on suction systems, or at the output of the submersible pump in a remote system. This provides a means of sealing off the tank for precision line testing without breaking pipe connections. The 325 PLIV can also be used for vapor line tank isolation on suction systems.
Proactively monitor for and remove the main corrosion-causing elements including water and moisture from diesel tanks and containment sumps with the Corrosion Control™ System.
Ensure proper vapor recovery every time by using the Air Interlock with Limit Switch. With the limit switch, bottom loading cannot begin until a vapor recovery hose is connected to the vapor check valve. The switch does its job by breaking a connection in the secondary over-fill prevention system, thus preventing the rack monitor from giving a green light to the transport. Once a vapor line is connected, loading can begin. The coupler first depresses the plunger button of the interlock, which then locks the trailer brake system and completes the connection to the rack monitor. The vapor hose must be disconnected before the brakes will release, allowing the truck to be driven away.
The EBW® vapor shear valve is designed for use as an emergency breakaway on Stage II vapor recovery lines in fuel dispensers. The double poppet design allows spring-loaded poppets inside the valve to seal vapors within both the dispenser riser and vapor piping in the event of dispenser displacement, providing maximum environmental protection.
Ball float vent valves are used in conjunction with extractor vent valves in the Stage I vapor riser or tank vent lines on underground storage tanks. The ball float vent valve will restrict vapor venting should a full tank condition occur and protects against product mixing and vapor locks due to vent pipe flooding. WARNING: 308 Series float vents should not be used with suction pump systems. For use on gravity drop systems only. Do not use with pump-off unloading. Do not use with coaxial Stage I vapor recovery drop tubes.
Available in 7½", 12", and 18" diameters, round cast iron manways feature a durable cast iron cover and skirt built to withstand heavy traffic loads.
The magnetic starter incorporates ambient compensated relays with quick trip heaters and three leg protection to assure proper 3 HP and 5 Hp pump motor protection.
Used to install, service, and test Defender Series® overfill prevention valves.
Air assisted emergency valves make product handling safer and installation more convenient. The emergency valve has a shear groove that meets 49 CFR 179.345-7. The seat of the valve is located inside of the tank shell as required by DOT regulations. One valve has the capability to be converted to either right or left hand control.
Emergency Valves make product handling safer. These Emergency Valves have a shear groove that meets 49 CFR 178.345-8. The seat area of the valve is located inside the tank shell as required by DOT regulations. This valve gives you the advantage of a faster flow rate while fitting a standard 4" TTMA sump. The high flow rate is established by a full opening throat area. Emergency Valves are available in 90° elbow type or straight type, 4" TTMA flanges or Victaulic™ outlet, and mechanical or air assisted.