Products for both loading and off-loading applications on tank truck transports.
EBW™ brand monitoring well filter wrap is used on the outside of monitoring well screen pipe to further prevent fine soil from entering and blocking the slots.
The EBW 325 product line isolation valve (PLIV) is designed to be installed at the top of the underground storage tank fuel line fitting on suction systems, or at the output of the submersible pump in a remote system. This provides a means of sealing off the tank for precision line testing without breaking pipe connections. The 325 PLIV can also be used for vapor line tank isolation on suction systems.
EBW pressure vacuum vents are used on storage tank vent pipes to discharge vapors upward into the atmosphere. The top casting is dome-shaped to quickly drain off moisture including rain, snow and ice. Body and cover are cast aluminum. 2" and 3" models have vent rates of 8000 cubic feet per hour, and produce 8.0 ounces of pressure and 0.5 ounces of vacuum.
The Side Seal Adapter is designed to give flexibility to top seal drop elbows. Your 4" top seal delivery elbow can now be used on a side 4" seal fill adapter. You don’t have to bring a separate side seal elbow, which reduces cost and the number of fittings required on your truck. Two lever clamps secure the adapter to the station’s side seal fitting and allow a 4" elbow to attach to the adapter. Special locking rings prevent accidental cam arm release during filling. Cast aluminum makes the side seal adapter light and strong. The specially designed seal gives you the added insurance that no leaks will occur.
Ball float vent valves are used in conjunction with extractor vent valves in the Stage I vapor riser or tank vent lines on underground storage tanks. The ball float vent valve will restrict vapor venting should a full tank condition occur and protects against product mixing and vapor locks due to vent pipe flooding. WARNING: 308 Series float vents should not be used with suction pump systems. For use on gravity drop systems only. Do not use with pump-off unloading. Do not use with coaxial Stage I vapor recovery drop tubes.
The System Integrity Testing Kit from Franklin Fueling Systems allows tightness testing of spill containers, tank access chambers and dispenser sumps to ensure air-tight seals and peace of mind. Specific testing at critical points during the installation process ensures that all components are installed correctly and that the complete installation is leak proof, preventing the need for an expensive rework.
The fill swivel adapter helps prevent leaks caused by constant fill delivery elbow movement on the riser adapter. The top section rotates during normal deliveries, preventing the bottom section from loosening on the riser pipe which could cause a vapor or product leak around the adapter.
By connecting to the site’s emergency stop system, Ethernet Primary Dispenser Disconnects provide low voltage disconnection for dispensers that use Ethernet network cabling for primary dispenser communication. Models are available that will disconnect 1 or 2 Ethernet cables for 8 dispensers or disconnect one Ethernet cable for 16 dispensers.
By connecting to the site’s emergency stop system, Twisted Pair Primary Dispenser Disconnects are designed to disconnect low voltage communication conductors. These conductors include dispenser data and credit card data two-wire, twisted pair circuits for a total of 4 conductors for up to 8, 12, or 16 dispensers.