Search


Results: 280 of 337
Below Grade

APT’s TS-2430, TS-3630 and TS-4230 tank sumps are ideally suited for low cost retro fits and shallow burial applications. The TS-2430 is ideal for line branching points and for containing piping splices. The 36" or 42" bases provide ample space for submersibles and fittings. The bolt-on gasket-lid combination fits economically under a 30" manway.


Below Grade Intermediate

The APT® below grade intermediate piping sump is a multifunctional component in the underground flexible piping system. The IPS-2424 and IPS-3636 can be used as a containment sump for fittings when utilizing a tee between dispenser islands, for contained piping splices, or for line branching points. These sumps are ideal for a low point sensor chamber between USTs and dispenser islands where required.


3" Float Vent Valves

3" × 3" × 2" BSPT for manifolded vents SS ball. Aluminium


Ducted Double Wall Rigid Entry Boot

APT® ducted double wall rigid entry boots allow you to create watertight connections between APT® 4” XP pipe and double wall fiberglass containment sumps. These boots are easily installed to the sump wall using adhesive (included) without the additional messy fiberglass work required. Rigid entry boots require only a single 3 ¾" entry hole for installation, eliminating the time-consuming process of drilling multiple holes as well as the templates they require.


Optimum Fusion

With the PetroTite Standard and Optimum fusion chambers the riser section electrofuses to the base, removing the need for multiple bolt holes and foam gaskets in this area, therefore dramatically reducing the number of potential leak paths. With its simplified assembly, this electrofusion system also reduces the installation time. Welding of the chamber can be performed using UPP electrofusion equipment in approximately six minutes. Once welded and cooled the base and riser of the OCH models become one homogeneous unit, with no mechanical joints and no leak points. The chamber can then be vacuum tested to ensure that it is 100% leak-tight. The Optimum chamber is available with either Deep or Shallow bases, and both will allow for a very easy installation of pipework before the riser is fused into place.


Vapor Shear Valves

The EBW® vapor shear valve is designed for use as an emergency breakaway on Stage II vapor recovery lines in fuel dispensers. The double poppet design allows spring-loaded poppets inside the valve to seal vapors within both the dispenser riser and vapor piping in the event of dispenser displacement, providing maximum environmental protection.


Anti-Kink Hose Clamp

Anti-kink hose clamps help to prevent costly hose replacements and fines that damaged hoses can lead to. The clamp provides a five-point bolt-down system to fully secure the hose into place and prevent it from sliding out of position and coming into contact with the ground. Anti-kink hose clamps keep hoses up off the pavement and islands, and away from vehicle tires. Hose run-overs can inflict permanent damage leading to obstructed fuel and vapor flow paths and unnecessary forecourt hazards.


PetroTite PE Fusion

With the PetroTite Standard and Optimum fusion chambers the riser section electrofuses to the base, removing the need for multiple bolt holes and foam gaskets in this area, therefore dramatically reducing the number of potential leak paths. With its simplified assembly, this electrofusion system also reduces the installation time. Welding of the chamber can be performed using UPP electrofusion equipment in approximately six minutes. Once welded and cooled the base and riser of the LA models become one homogeneous unit, with no mechanical joints and no leak points. The chamber can then be vacuum tested to ensure that it is 100% leak-tight. The LA Chamber is available in Deep or Shallow risers.


Pipe Guards & Bollards

Protect property and avoid costly damage to dispensers with these schedule 40 pipe guards and bollards.


Shear Valves

FLEX-ING™ brand 1½" diesel exhaust fluid shear valves shut off the flow of DEF/AdBlue® in the event of a vehicle collision with a dispenser preventing an excessive and uncontrolled release into the environment. The optional e-coated mounting bracket allows installation both in containment sumps beneath the dispenser as well as direct mounting to the concrete forecourt.