Petroleum Control Solutions

Petroleum Control Solutions - Hero.psd

Petroleum Control Solutions

For retail fueling and c-store applications, Power Distribution Solutions provide a complete petroleum control, power distribution, and backup power / generator transfer switching solution for an entire location.

  • Provides AC power controls required for a typical retail petroleum application.

  • Includes emergency stop and service disconnects for dispenser low voltage wiring.

  • Optional low voltage circuit disconnects.

  • Optional series connected surge suppression for protection of sensitive electronic circuits.

  • Individual pump and dispenser contactors allow connection of remote control or monitoring system.

  • Pump handle isolation using solid state technology with error detection.

  • Marked terminals for easy connection of dispensers, pumps, card readers, fuel management systems and tank monitors.

  • Factory assembled and pre-wired, eliminating mounting and wiring of separate components in the field.

AC Power Control Capabilities

  • E-stop & reset push buttons
  • Emergency stop controls.
  • Pump hook isolation.
  • Pump status lights.
  • Pump contactors.
  • Dispenser contactors.

Dispenser Capabilities

  • Low voltage disconnect.
  • Low voltage protection.

Enclosure Options

  • UL Type 1 indoor.

Certifications/Approvals

  • UL Listed.
  • cUL Listed.
  • For compliance with NEC® 514.11 and NFPA® 30A Section 6.7 requirements for Emergency Disconnects at Motor Fuel Dispensing Facilities (controlled by E-Stop system).
  • For compliance with NEC® 514.13 requirements for Maintenance Disconnects at Motor Fuel Dispensing Facilities (switches to disconnect individual dispenser circuits for servicing).

General

Dispenser Capacity 4, 6, 8, 10, & 12
Submersible Pump Capacity 2 - 6
Dispenser Data Circuits 1 Data Pair, 1 Credit Card Pair
Intercom Circuits 1 Speaker, 1 Call Button per Dispenser (4 Conductors)
2 Speakers, 2 Call Buttons per Dispenser (8 Conductors)
Media Circuits Ethernet Circuits
2-Wire Circuits

System Components

The Petroleum Control Solutions can be installed with or without integrated low voltage circuit disconnects.

  1. Petroleum Control Solution
  2. Petroleum Control Solution with Low Voltage Disconnects
  3. E-Stop Operator
  4. Reset Operator
  5. Pump Run Indicators
  6. Primary Disconnect
  7. Secondary Disconnect
PCS - Specs - Dims 1.psd

Ordering Guide

Complete part numbers have a specific order and are created using the following guidelines:

 

PCS-XDS YPS-N DGWT CB EQR

PCS = Petroleum Control System

XD = # of Dispensers
4 = 4 Dispensers
6 = 6 Dispensers
8 = 8 Dispensers
10 = 10 Dispensers
12 = 12 Dispensers

S = Dispenser Disconnect Switch (optional)

YP = # of Pumps
2 = 2 Pumps
3 = 3 Pumps
4 = 4 Pumps
5 = 5 Pumps
6 = 6 Pumps

S = Dispenser Disconnect Switch (optional)

N DGWT CB EQR = Low Voltage Circuit Disconnects
N = No Low Voltage Disconnect Options
or
DGWT CB EQR = Low Voltage Disconnect Options

D or G or W or T = Dispenser Data (choose one)
D = Twisted Pair (No data surge protection)
G = Twisted Pair with data surge protection for current loop
W = Twisted Pair with data surge protection for current loop & RS-485
T = Ethernet

C or B = Intercom Data (choose one)*
C = 4 conductors per dispenser
B = 8 conductors per dispenser

E or Q or R = Media/Network Data (choose one)*
E = Ethernet
Q = 4 conductors per dispenser
R = 8 conductors per dispenser

 

Examples:

PCS-6DS4P-GB = Petroleum Control Solution, (6) dispensers, (4) pumps, with Twisted Pair (with Data Surge Protection for Current Loop) Low Voltage Dispenser Data Disconnects, with (2) Speakers & (2) Call Buttons per Dispenser.

PCS-12D6P-TBE = Petroleum Control Solution, (12) dispensers, (6) pumps, with Ethernet Low Voltage Dispenser Data Disconnects, with (2) Speakers & (2) Call Buttons per Dispenser, with Ethernet Media/Network Data circuit.

PCS-6D4PS-N = Petroleum Control Solution, (6) dispensers, (4) pumps, Pump Disconnect Switch, No Low Voltage Disconnects.

*Dispenser Data Disconnect must be selected for secondary Disconnect Options (e.g. D,G,W, or T)