EVO™ 200 & EVO™ 400
EVO™ 200 & EVO™ 400
EVO™ 200 & EVO™ 400 Automatic Tank Gauges (ATGs) provide highly accurate inventory management and containment monitoring for small to mid-size fuel systems.

NEVER STOP EVOLVING
We are driven by our pursuit to innovate, simplify, secure, and connect every station owner to their fuel management system. EVO™ 200 and EVO™ 400 ATGs feature simple setup and operation, remote connectivity, and advanced security features to protect your fuel system while keeping you directly connected to vital site data whenever, and wherever.

A full-color 7” LCD touchscreen serves up one of the most intuitive user interfaces available with simplified user features you won’t find anywhere else. You choose your home screen, you program your product colors, and you choose what shows up on your Favorites screen. Customize the interface to meet your business needs the way you operate. Check out the interactive demo below.
CLICK ON THE INTERACTIVE TOUCHSCREEN BELOW

Icon-Based Design
Designed to be understood easily and operated intuitively. It’s simple to operate for new users and can reduce the amount of training required to operate.

One Touch Buttons
You can customize these home screen buttons to automate and carry out anything from complex, multi-function processes to simple daily delivery report generation - all with the touch of a single button.

Quick Jump Menu
Navigate quickly from application to application with ease. This time-saving menu makes the interface’s structure extremely shallow, simple to navigate, and reduces the amount of steps it takes to accomplish tasks.

EVO™ Series ATGs help keep sites in compliance while providing marketers with the highest level protection from the security threats facing our industry.
User Roles
Customizable user roles and log-in security protect against unwanted access and track user activity.
Data Back-Up
Stores up to 3-years of data to provide back up security from power outages or other system interruptions.
Secure WiFi
Optional WiFi allows secure and protected onsite viewing of inventory levels for fuel delivery drivers.

The FFS PRO® Connect web interface allows you to securely connect directly to your EVO™ Series ATG from any web enabled device. It automatically scales for tablets and smart phones, meaning no app to download.
INTERACTIVE DEMO
FFS PRO® CONNECT
FFS PRO® Connect displays real-time data allowing precise delivery scheduling and efficient site management. It also provide immediate notification of alarms so quick corrective actions can be taken.

Turbine Pump Interface is a powerful tool that creates a network between your Submersible Turbine Pump (STP) controllers and EVO™ Series ATGs. Through TPI, the tank gauge can be programmed to respond to faults in the submersible pumping system and react with intelligence that pump controllers alone cannot.
SEE TPI IN ACTIONPump In Water Automation
When the water level in a tank approaches the pump intake, the tank gauge will enter alarm mode and automatically shut down the pump, protecting the system and consumers from water being pumped from that tank.
Leveling & Priority Modes
When managing two storage tanks of the same product ‘Leveling Mode’ can keep both tanks at the same percentage full without the use of a syphon bar between the two tanks.
Remote Pump Interaction
By networking the intelligent controllers to the fuel management system via TPI, a technician can remotely connect to the site to review the logged event history and view the status.

The EVO™ Series family of ATGs offers four different options with right-sized features to meet the requirements of your specific application, size, and compliance needs. Which ATG is right for your application?
ATG SELECTION GUIDEWith pre-configured hardware and customizable software options, these ATGs provide straightforward tank level monitoring and compliance. Their simple setup and operation, remote connectivity, and advanced security features protect your fuel system while keeping you directly connected to vital site data whenever, and wherever.
- Provides inventory monitoring, static (included feature) and continuous tank testing (optional feature), tank autocalibration, inventory reconciliation, flow rate monitoring and containment compliance monitoring.
- Both ATGs feature the capability to interface with probes and sensors in any combination up to 6 (EVO™ 200) or 14 (EVO™ 400).
- Customizable user roles and log-in security features protect against unwanted access while keeping track of user activity within your system.
- Streamlined setup and programming includes hardware auto-detection and wiring confirmation, multipoint tank charting, network printer auto-detection, and the ability to download and upload entire programming profiles from one ATG to another.
- Available with optional 24-hour Statistical Continuous Automatic Leak Detection (SCALD) and Turbine Pump Interface (TPI) capability for enhanced and automated submersible turbine pump control.
- Web interface allows you to directly connect to your ATG via FFS PRO® Connect from any web-enabled device.
- Optional Wifi allows secure and protected on-site viewing of inventory levels for fuel delivery drivers.
- Intuitive full-color 7" (17.78 cm) touch screen interface provides simplified on-site access features including:
- Six available One Touch buttons that are custom programmed to carry out common automated tasks with a single tap.
- Quick Jump menu allows you to quickly maneuver from application to application using a single button.
- Programmable product colors.
- Six available One Touch buttons that are custom programmed to carry out common automated tasks with a single tap.
Components

- Cover
- LCD touch screen
- LED indicators
- Anunciator (audible alarm)
- RS-485
- Mini USB port
- Ethernet / USB port
- RS-232
- Knockouts
- Mounting holes
- Flip up panel (touch screen)
- Termination blocks
- Main board
General
- Maximum tanks monitored: 6 (EVO™ 200) / 14 (EVO™ 400)
- Maximum sensor input capacity: 6 (EVO™ 200) / 14 (EVO™ 400)
- Total # of inputs: 6 (EVO™ 200) / 14 (EVO™ 400)
- Dry contact input channels: 2
- Relay output channels: 2
- Connectivity: Ethernet, RS-232, RS-485, standard USB, mini USB, and Wifi (optional)
- Display type: 7” (17.78 cm) color LCD touch screen
- Printer support: External (network or USB)
- Alarm: Internal audible alarm
- LEDs: Alarm, warning, and power
- Tank chart correction points: 7,500
- Applicable liquids: Petroleum, chemicals, and waste oil
- Level units: Inches, centimeters, and millimeters
- Volume units: gallons or liters (mass with density option)
- Power requirements: 110 to 240 VAC, 50/60 hz, 1.0 Amps max.
- Operating temperature: 32° to 104 °F (0° to 40 °C)
- Humidity: 0-90% non-condensing
- Dimensions: Height: 8” (205mm), Width:13 ¾” (350mm), Depth: 3¼” (83mm)
Capabilities
- High/low product, water, and temperature alarm set points
- Inventory reconciliation / tank auto-calibration / flow rate monitoring (optional)
- Density, mass, and phase separation measurement
- Email and SMS notifications
- Back-up generator monitoring
- MODBUS™ support
Approvals/Certifications
- UL, cUL, ATEX, IECEx
- Third party certification of leak detection capabilities
Ordering Guide
ATG model, software and hardware options can be listed separately or combined when ordering. Systems shipped from the factory will list the combined part number. Complete part numbers have a specific order and are created using the following guidelines:
EVOX DW - TRFC
- EVOX = Base Model Options
- EVO200 = EVO™ 200 base model, up to 6 channels
- EVO400 = EVO™ 400 base model, up to 14 channels
- DW = Hardware Options (choose all that apply)
- D = Display (color LCD touch screen)
- W = Wifi
- TR = Software Options (choose all that apply)
- T = SCALD 24-hour tank testing
- R or F
- R = Reconciliation/Autocalibration
- F = Reconcilliation/Autocalibration with flow rate monitoring
- C = Enhanced logic conditions including value, counter, value compare, and latch
Example: EVO400DW-TR = EVO™ 400 base model, up to 14 channels with display, with Wifi, with SCALD, and with Reconcilidation/Autocalibration.
EVO™ 200 & EVO™ 400 Base Models
Model Number | Description |
---|---|
EVO200 | EVO™ 200 base model automatic tank gauge, up to 6 channels |
EVO400 | EVO™ 400 base model automatic tank gauge, up to 14 channels |
EVO™ 200 & EVO™ Hardware & Software Options
EVO™ 200 and EVO™ 400 ATGs come standard with the ability to perform in-tank static leak detection. The following software and hardware options can be added to customize your ATG. The internal hardware options will be factory installed when ordered with the ATG.
Internal Hardware Options (200/400)
Model Number | Description |
---|---|
FMP-LCD | (D) Display (color LCD touch screen) |
FMP-SOMW-U | Unregistered upgrade SOM with WIFI |
FMP-SOMW-UR | Registered upgrade SOM with WIFI |
Internal Software Options (200/400)
Model Number | Description |
---|---|
TS-TRAC | (R) Tank inventory reconciliation and autocalibration |
TS-TRAC-F | (F) Reconciliation/autocalibration and flow rate monitoring software |
TS-TT | (T) Statistical Continuous Automatic Leak Detection, 24 hour continuous tank testing software |
TS-CON | (C) Enhanced logic conditions including value, counter, value compare, and latch |
External Printer
Model Number | Description |
---|---|
FMP-EPPC | Case of 25 thermal printer paper rolls |
FMP-ETP | External printer, includes USB cable, power cord, one roll of thermal printer paper, and wall mount hardware |
- The external printer measures 142mm X 132mm X 204mm (w x h x d) and can be mounted to wall next to the EVO™ Series ATG using the included hardware).
Featured
Brochures
Title | Type | Size | |
---|---|---|---|
![]() |
FFS-0792 EVO Series Brochure.pdf | 11.67 MB | |
![]() |
FFS-0618 EVO 200 & EVO 400 ATG Datasheet.pdf | 3.94 MB | |
![]() |
FFS-0791 EVO Series Selection Guide.pdf | 5.28 MB |
Catalogs
Title | Type | Size | |
---|---|---|---|
![]() |
FFS-0216 (UL) FFS Product Catalog.pdf | 20.25 MB | |
![]() |
FFS-0220 (EN) Fuel Management Systems Catalogue.pdf | 14.45 MB |
Drawings
Title | Type | Size | |
---|---|---|---|
![]() |
CD_FMS_TS-EXPC_001.pdf | 0.09 MB | |
CD_FMS_TS-EXPC_001.dwg | DWG | 0.48 MB | |
![]() |
CD_FMS_EVO600_001.pdf | 0.1 MB | |
CD_FMS_EVO600_001.dwg | DWG | 0.38 MB | |
![]() |
CD_FMS_EVO 400_001.pdf | 0.38 MB | |
CD_FMS_EVO 400_001.dwg | DWG | 1.25 MB |