Defender Series®

Spill Containers

Defender Series Spill Containers.psd
Defender Series®

Spill Containers

Defender Series® single and double wall spill containers, available in both grade level and below grade models, provide a durable, easy-to-install, and simple-to-maintain and service spill containment solution for any environment and any application.

Defender Series Spill Containers - Highlight.psd

SPILL CONTAINMENT IS A DIRTY JOB

Defender Series® five-gallon spill containers combine years of knowledge and experience in forecourts across the globe to represent the best defense in spill containment. Proactively protecting a site from the dangers of fugitive emissions during fuel delivery can save station owners both time and money by avoiding remediation due to fuel leakage.


Grade Level or Below Grade

Defender Series® spill containers are available in either grade level or below grade level models to meet the needs of your environment, weather conditions, local regulations, and preferred fuel drop application.

Built to Last

Defender Series® spill containers are built tough with cast iron powder-coated frames, high density polyethylene double-wall containers, and epoxy-coated cast iron lids - made to handle any environment.

Easy Installation & Maintenance

From their quick installation, to easy testing, and simple maintenance, Defender Series® spill containers deliver a high-value spill containment solution that keeps on delivering from day one and beyond.

TECHNICAL ADVANTAGES

FFS-SpillContainer-Illustration-Installation.png

Variable Installation Height

Jobsites can throw anything at you. A variable installation height adjustment feature makes it easy to ensure proper installation height at grade level.

FFS-SpillContainer-Illustration-ComplianceTesting.png

Compliance Testing

An integrated visual interstitial integrity monitor makes EPA-mandated 30-day visual inspections fast, clean, and easy.

FFS-SpillContainer-Illustration-Maintenance.png

Easy Drop Tube Removal

The drop tube riser adapter provides a clean sealing ledge for the drop tube gasket, ensuring a vapor tight seal and the ability to smoothly pull the drop tube and overfill prevention valve for maintenance.

Defender Series Spill Containers - Install Wide.psd
CHOSE THE RIGHT SOLUTION FOR YOUR APPLICATION

Defender Series spill containers are available in both grade level and below grade level models to meet the needs of your application.

Defender Series Spill Containers - Below Grade.psd

Below Grade Spill Containers

Double wall containment protected by a solid steel manway skirt. The flush fiberglass composite manway lid allows forecourt traffic to pass cleanly over top while a gasketed lock-down cover seals water out.

Defender Series Spill Containers - Grade Level.psd

Grade Level Spill Containers

Double wall containment protected by a solid steel manway skirt. The flush fiberglass composite manway lid allows forecourt traffic to pass cleanly over top while a gasketed lock-down cover seals water out.

WE MAKE INSTALLATION EASY

Defender Series® Spill containers bring their A-game to the jobsite at installation.

Defender Series Spill Containers - Below Grade Install.psd

Below Grade Install

Below grade spill containers install easily, and cleanly into the included 18” manway for simple installation.

Defender Series Spill Containers - Grade Level Install.psd

Grade Level Install

Grade level spill containers offer variable installation height adjustment making it easy to ensure proper installation height.

Defender Series Spill Containers - Compliance Wide.psd
INTERSTITIAL INTEGRITY TESTING
Depending on local state regulations, your double wall spill containers may require ongoing visual inspection, vacuum testing, or hydrostatic testing to ensure the integrity of the interstitial space. Defender Series® spill containers allow you to score huge efficiencies when it comes to meeting these regulations.
Defender Series Spill Containers - Visual Monitor.psd

Visual Monitor

The integrated visual interstitial integrity monitor options makes EPA-mandated 30-day visual inspections fast, clean, and easy.

Defender Series Spill Containers - Electronic Monitor.psd

Sensor Monitor

An integrated electronic sensor monitoring option interfaces with your ATG to provide continual monitoring and instant alerts regarding the spill container’s double wall integrity.

Spill Container Vacuum Testing.psd

Vacuum Testing

Defender Series® spill containers can be easily vacuum tested through the inspection port using our Vacuum Testing Kit.
READY FOR 30-DAY INSPECTIONS
As part of the EPA federal UST regulation updates regarding spill containment inspection and testing that went into effect in October 2018, a walk-through visual inspection is required every 30-days to check for water intrusion, damage, and double wall interstitial integrity. See how the Defender Series® double wall spill containers will have you ready for each of these three components of the inspection.
Defender Series Spill Containers - 30-Day Testing.psd

Defender Series® Double Wall Spill Containers Make It Easy

Defender Series Spill Containers - Water Intrusion.psd

Water Intrusion

A visual inspection to ensure dry, liquid-free containment with no water intrusion.

Double wall spill containers include 11 internal gasketed seals to keep your spill containers dry.

Defender Series Spill Containers - Damage.psd

Damage

A visual inspection to ensure there are no cracks or damage to the spill container.

The solid, one-piece, non-bellowed construction of both the primary and secondary spill container give them superior strength against forecourt traffic and ground movement.

Defender Series Spill Containers - Visual Monitor.psd

Interstitial Integrity

A visual inspection for double wall spill containers to ensure the space between the primary and secondary is tight.

The I2 (interstitial integrity) monitor provides an oversized, easy-to-read dial that provides immediate confirmation of the integrity of the interstitial space with an optional electronic sensor option also available.

EASY TO MAINTAIN & SERVICE

Added maintenance and service design features keep your spill containers in the ground for a long, long time. 

Defender Series Spill Containers - Drop Tube Riser.psd

Drop Tube Riser

The drop tube riser adapter provides a clean sealing ledge for the drop tube gasket, ensuring a vapor tight seal and the ability to cleanly and smoothly pull the drop tube and overfill prevention valve for maintenance.

Defender Series Spill Containers - Drain.psd

Integrated Drain

A push-pull drain option allows the fuel delivery drivers to send any fuel overfill captured by the spill container during a drop into the tank.

Defender Series Spill Containers - Upgrade.psd

Easy Updgrade

The thread-on base integrated into both the primary and secondary spill containers allow you to easily install and replace either container without having to break concrete should a breach occur or if you need to upgrade from single to double wall .

Approvals/Certifications

  • UL Listed MH62435 (below grade, and grade level version with CI-GKT cover), ULC Listed (grade level CI-GKT versions only).
  • CARB approved (grade level only).
  • Covers are engineered and tested to meet or exceed H20 and HS-20 load ratings.
  • UL2447 listed for only those fuels formulated in accordance with 40CFR80, “Regulation of Fuels and Fuel Additives,” and meeting the following ASTM fuel specifications and blend limit:
  • ASTM D975 diesel with or without biodiesel blends up to 5% (B5)
    • ASTM D7467 diesel with biodiesel blends between 6% - 20% (B6 - B20)
    • ASTM D4814 gasoline with ethanol blends up to 10% (E10)
    • ASTM D5798 high-blend ethanol, with ethanol/gasoline blends between 51% - 83% (E51 - E83) - commercially known as “E-85”
    • Mid-range ethanol, with ethanol/gasoline blends of ASTM D4814 and ASTM D5798 blends between 11% - 50% (E11 - E50)
  • In addition to UL2447 listed fuels, the following fuels are also compatible:
    • Biodiesel up to 5% B5
    • Biodiesel up to 20% B20
    • Biodiesel at 97%-100% B99/B100
    • All ASTM biofuel blends

Components

Defender Series Spill Containers - Comps.psd
  1. Adapter cap
  2. Swivel adapter
  3. Nipple
  4. Drop tube adapter
  5. Drain
  6. Visual monitor
  7. Electronic sensor monitor
  8. Lock down lid
  9. 18” manway
  10. Fiberglass manyway lid
  11. Gravel guard
  12. Cast iron gasketed lid

Grade Level Spill Container Dimensions

Defender Series Spill Containers - Grade Level Dims.psd

Below Grade Spill Container Dimensions

Defender Series Spill Containers - Below Grade Dims.psd

Configurations

Defender Series Spill Containers - Configs.psd

Ordering Guide

Complete spill container part numbers have a specific order and are created using the following guidelines:

705 XXX Y A B C

XXX = Containment Options

  • 545 = Grade level single wall
  • 555 = Grade level double wall
  • 556 = Below grade double wall

Y = Interstitial Monitoring Options

  • 0 = No sensor
  • 1 = Visual monitor (float gauge)
  • 2 = Electronic sensor monitor

A = Base Thread Options

  • 0 = NPSM
  • 1 = NPT
  • 2 = BSPT

B = Drain Options

  • 1 = with Drain
  • 2 = without Drain

C = Lid/Cover

  • BLK = Black fiberglass 18” manway cover (below grade only)
  • CI-GKT = Black epoxy-coated cast iron gasketed lid (grade level only)
  • CI-GRN = Green epoxy-coated cast iron gasketed lid (grade level only)
  • CI-ORG = Orange epoxy-coated cast iron gasketed lid (grade level only)
  • CI-RED = Red epoxy-coated cast iron gasketed lid (grade level only)
  • CI-WHT = White epoxy-coated cast iron gasketed lid (grade level only)
  • CI-YEL = Yellow epoxy-coated cast iron gasketed lid (grade level only)

 

Example: 705555111CI-GKT = Defender Series® grade level double wall spill container with visual monitor, with NPT base thread, with drain and with black cast iron gasketed lid.

Example: 705556211BLK = Defender Series® below grade double wall spill container with electronic sensor monitor, with NPT base thread, with drain and with black fiberglass manway cover (manyway included).

Defender Series® Spill Containers Common Configurations

Model Number Description
705545001CI-GKT Defender Series® grade level, single wall, NPSM thread, with drain, with black epoxy-coated cast iron gasketed lid
705545002CI-GKT Defender Series® grade level, single wall, NPSM thread, without drain, with black epoxy-coated cast iron gasketed lid
705545011CI-GKT Defender Series® grade level, single wall, NPT thread, with drain, with black epoxy-coated cast iron gasketed lid
705545012CI-GKT Defender Series® grade level, single wall, NPT thread, without drain, with black epoxy-coated cast iron gasketed lid
705545021CI-GKT Defender Series® grade level, single wall, BSPT thread, with drain, with black epoxy-coated cast iron gasketed lid
705545022CI-GKT Defender Series® grade level, single wall, BSPT thread, without drain, with black epoxy-coated cast iron gasketed lid
705555101CI-GKT Defender Series® grade level, double wall, NPSM thread, with drain, with visual monitor, with black epoxy-coated cast iron gasketed lid
705555102CI-GKT Defender Series® grade level, double wall, NPSM thread, without drain, with visual monitor, with black epoxy-coated cast iron gasketed lid
705555111CI-GKT Defender Series® grade level, double wall, NPT thread, with drain, with visual monitor, with black epoxy-coated cast iron gasketed lid
705555112CI-GKT Defender Series® grade level, double wall, NPT thread, without drain, with visual monitor, with black epoxy-coated cast iron gasketed lid
705555211CI-GKT Defender Series® grade level, double wall, NPT thread, with drain, with electronic sensor monitor, with black epoxy-coated cast iron gasketed lid
705555212CI-GKT Defender Series® grade level, NPT thread, without drain, with electronic sensor monitor, with black epoxy-coated cast iron gasketed lid
705556111BLK Defender Series® below grade, double wall, NPT thread, with drain, with visual monitor, with black fiberglass manway cover (18" manway included)
705556112BLK Defender Series® below grade, double wall, NPT thread, no drain, with visual monitor, with black fiberglass manway cover (18" manway included)
705556211BLK Defender Series® below grade, double wall, NPT thread, with drain, with electronic sensor monitor, with black fiberglass manway cover (18" manway included)
705556212BLK Defender Series® below grade, double wall, NPT thread, no drain, with electronic sensor monitor, with black fiberglass manway cover (18" manway included)

Defender Series™ Spill Container Installation Tools

Model Number Description
T-7001

T-handle, attaches to all installation adapter tools

T-7106

Defender Series® spill container tool, used to install and remove both below grade and grade level spill containers

T-7107

Defender Series® spill container double wall vacuum test tool

Grade Level Single Wall Replacement Parts

Model Number Description
70544011 Cover, cast iron w/gasket (black)
70551911 Cover gasket
70553001 Plow ring assembly
602009007 Plow ring gasket
70541202

Fill swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel fill swivel adapter, 3” riser nipple, fill top cap.

77720102 Top seal fill cap
SWF-100-SS

Fill swivel adapter, 4” NPT, stainless steel

70521307 4" x 2.88" close nipple
70541302 Vapor swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel vapor swivel adapter, 3” riser nipple, vapor top cap.
30430103 Epoxy coated aluminum, AGB
SWV-101-SS

Vapor swivel adapter, 4” NPT, stainless steel

70550901EC DT riser clamp assembly
1103939 DT riser gasket
70533729 Pull-to-push drain valve kit
70550311 Spill container seal ring gasket
602256001 Tank riser gasket
705545001SP Defender Series® Grade level 5 gallon spill container, single wall, with drain, NPSM thread, with replacement bucket
705545002SP Defender Series® Grade level 5 gallon spill container, single wall, without drain, NPSM thread, with replacement bucket
705545012SP Defender Series® Grade level 5 gallon spill container, single wall, without drain, NPT thread, with replacement bucket
705545011SP Defender Series® Grade level 5 gallon spill container, single wall, with drain, NPT thread, with replacement bucket

Grade Level Double Wall Replacement Parts

Model Number Description
70544011 Cover, cast iron w/gasket (black)
70551911 Cover gasket
70553001 Plow ring assembly
602009007 Plow ring gasket
70541202

Fill swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel fill swivel adapter, 3” riser nipple, fill top cap.

77720102 Top seal fill cap
SWF-100-SS

Fill swivel adapter, 4” NPT, stainless steel

70521307 4" x 2.88" close nipple
70541302 Vapor swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel vapor swivel adapter, 3” riser nipple, vapor top cap.
30430103 Epoxy coated aluminum, AGB
SWV-101-SS

Vapor swivel adapter, 4” NPT, stainless steel

70550901EC DT riser clamp assembly
1103939 DT riser gasket
70533729 Pull-to-push drain valve kit
70553301 I2 monitor and inspection port kit
TSP-ULS Universal liquid sump sensor (New orders for use with S940 only)
70553302 Sensor inspection port
70550311 Spill container seal ring gasket
602256001 Tank riser gasket
705555101SP Defender Series® Grade level 5 gallon spill container, double wall, with drain, NPSM thread, with I2 monitor, cast-iron yellow cover with gasketed lid, AGB compatible
705555102SP Defender Series® Grade level 5 gallon spill container, double wall, without drain, NPSM thread, with I2 monitor, cast-iron yellow cover with gasketed lid, AGB compatible
705555111SP Defender Series® Grade level 5 gallon spill container, double wall, with drain, NPT thread, with I2 monitor, cast-iron yellow cover with gasketed lid, AGB compatible
705555112SP Defender Series® Grade level 5 gallon spill container, double wall, without drain, NPT thread, with I2 monitor, red FRC cover, AGB compatible
705555201SP Defender Series® Grade level 5 gallon spill container, double wall, with drain, NPSM thread, with sensor, with replacement bucket
705555202SP Defender Series® Grade level 5 gallon spill container, double wall, without drain, NPSM thread, with sensor, with replacement bucket
705555211SP Defender Series® Grade level 5 gallon spill container, double wall, with drain, NPT thread, with sensor, with replacement bucket
705555212SP Defender Series® Grade level 5 gallon spill container, double wall, without drain, NPT thread, with sensor, with replacement bucket

Below Grade Double Wall Replacement Parts

Model Number Description
78130401 18" (457 mm) black FRC replacement cover
705587901 Lock down cover assembly
71520201 Spare lift handle assembly, below grade containers
70541202

Fill swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel fill swivel adapter, 3” riser nipple, fill top cap.

77720102 Top seal fill cap
SWF-100-SS

Fill swivel adapter, 4” NPT, stainless steel

70521307 4" x 2.88" close nipple
70541302 Vapor swivel adapter kit for 5 gallon Defender Series® (grade level and below grade level) and EBW® Series (grade level) spill containers, includes stainless steel vapor swivel adapter, 3” riser nipple, vapor top cap.
30430103 Epoxy coated aluminum, AGB
SWV-101-SS

Vapor swivel adapter, 4” NPT, stainless steel

70550901EC DT riser clamp assembly
1103939 DT riser gasket
70533729 Pull-to-push drain valve kit
70553303 I2 monitor and inspection port kit
TSP-ULS Universal liquid sump sensor (New orders for use with S940 only)
70553302 Sensor inspection port
602256001 Tank riser gasket

Assets